The followig table contains the code sequence of the LSS services to change node-id and baudrate. Text in red is the responce of the drive. 

LSS Code Sequence

COB-Id Data Description
0 81 00 reset node, second byte is node-id, 0 → all nodes
701 00 bootup message, orignal node-id
7E5 04 01 switch to configuration mode
7E5 11 02 config node-id, second byte is node-id
701 00 bootup message, orignal node-id
7E4 11 00 00 00 00 00 00 00 response to config node-id
7E5 13 00 02 config baudrate, third byte is baudrate, see table below
7E4 13 00 00 00 00 00 00 00 response to config baudrate
7E5 17 store configured parameters
7E4 17 00 00 00 00 00 00 00 response to store configured parameters
7E5 15 C8 activate bit timing, second byte defines delay in ms
switch host-baudrate
7E5 04 00 switch to operation mode
702 00 bootup message, new node-id

Baudrates of standard table 0x00

Table index Baudrate/kBit/s
0 1000
1 800
2 500
3 250
4 125
5 reserved
6 50
7 20
8 10